Technical Data
User manual 9000-41011-0200000_hdb_en_20 36 / 92
4.3 Mico Pro PD (power distribution)
4.3.1 Electrical data
4.3.1.1 Input
4.3.1.2 Output
4.3.2 Environmental characteristics
4.3.2.1 Climatic
Parameter Conditions Value
Operating voltage 12 V , 24 V
Input voltage range 9 V ... 30 V
Total operating current continuous
jumper
Plug-In link ≤20 A
Variants input current
Art.-No. Parameter Conditions Value
9000-41000-0000212 Max. input current Total 20 A
9000-41000-0002206 Max. input current To t al 2x20 A
Variants output current
Art.-No. Parameter Conditions Value
9000-41000-0000212 Output current (I
∑
) Total ≤20 A
Output current Per clamp
(U+ / 0 V)
≤20 A
9000-41000-0002206 Output current (I
∑
) Total ≤2x20 A
Output current Per clamp
(U1 / U2 / 0 V)
≤20 A
Symbol Parameter Conditions Value
Relative humidity No condensation 5 ... 85 %
Storage temperature -40 ... +80 °C
Climate class IEC/EN 60721-3-3 3K3
Ta Surrounding air temperature
range
-25 ... +55 °C
Variants installation height
Art.-No. Parameter Conditions Value
9000-41000-0000212 Installation height Above sea level,
without any restric-
tions
-500 m ... 2000 m
Installation height Above sea level,
max. 16 A total oper-
ating current
2000 m ... 4000 m
Installation height Above sea level,
max. 12 A total oper-
ating current
4000 m ... 6000 m