Technical Data
User manual 9000-41011-0200000_hdb_en_20 37 / 92
4.3.2.2 Mechanical
4.3.2.3 Electrical safety
4.3.2.4 EMC-interference
4.3.2.5 EMC-immunity
9000-41000-0002206 Installation height Above sea level,
without any restric-
tions
-500 m ... 2000 m
Installation height Above sea level,
max. 2x16 A total op-
erating current
2000 m ... 4000 m
Installation height Above sea level,
max. 2x12 A total op-
erating current
4000 m ... 6000 m
Variants installation height
Art.-No. Parameter Conditions Value
Parameter Conditions Value
Vibration test IEC 60068-2-6:2007 Test
Fc;
EN 60068-2-6:2008
sin 5 ... 17.8 Hz: 1.6
mm;
17.8 ... 500 Hz: 2.3 g
10x f
Shock test IEC 60068-2-27:2008 Test
Ea;
EN 60068-2-27:2009
1/2 sin 30 g, 11 ms
Shocks caused by rough handling (Drop test) 1 m
Parameter Conditions Value
Degree of protection EN 60529 IP20
Pollution degree 2
Overvoltage category III
Insulation voltage
input-output
Type testing / routine check
test
50 V
Parameter Conditions Value
Radio interference field strength
housing
EN 61000-6-3 Industrial and residu-
al areas
Conducted emission
DC inputs and outputs
EN 61000-6-3 Industrial and residu-
al areas
Parameter Conditions Value
Fast transients / burst
DC inputs and outputs
EN 61000-6-2,
EN 61000-4-4
±2 kV / 5 kHz
Fast transients / burst
signal connections
EN 61000-6-2,
EN 61000-4-4
±2 kV / 5 kHz
Surge voltage
DC inputs and outputs
EN 61000-6-2,
EN 61000-4-5
±0.5 kV DM
Electrostatic discharge housing EN 61000-6-2,
EN 61000-4-2
Contact ±4 kV; air ±8 kV
Conducted HF
DC connections
EN 61000-6-2,
EN 61000-4-6
10 VRMS; 1 kHz,
80 % AM sine
Conducted HF
control terminals
EN 61000-6-2,
EN 61000-4-6
10 VRMS; 1 kHz,
80 % AM sine
High-frequency electrical
RF fields housing
EN 61000-6-2,
EN 61000-4-3
80 MHz ... 1.0 GHz: 10 V/m

Table of Contents