Technical Data
User manual 9000-41011-0200000_hdb_en_20 40 / 92
4.4 Mico Pro Plug-In link
4.4.1 Electrical data
4.4.1.1 Input
4.4.2 Environmental characteristics
4.4.2.1 Climatic
4.4.2.2 Mechanical
4.4.2.3 Electrical safety
Parameter Conditions Value
Operating voltage 12 V , 24 V
Input voltage range 9 V ... 30 V
Total operating current continuous
jumper
Plug-In link 40 A
Output current 40 A
Symbol Parameter Conditions Value
Relative humidity No condensation 5 ... 85 %
Storage temperature -40 ... +80 °C
Climate class IEC/EN 60721-3-3 3K3
Ta Surrounding air temperature
range
-25 ... +55 °C
Installation height Above sea level,
without any restrictions
-500 m ... 2000 m
Installation height Above sea level,
max. 32 A total operat-
ing current
2000 m ... 4000 m
Installation height Above sea level,
max. 24 A total operat-
ing current
4000 m ... 6000 m
Parameter Conditions Value
Vibration test IEC 60068-2-6:2007 Test
Fc; EN 60068-2-6:2008
sin 5 ... 17.8 Hz: 1.6
mm;
17.8 ... 500 Hz: 2.3 g
10x f
Shock test IEC 60068-2-27:2008 Test
Ea; EN 60068-2-27:2009
1/2 sin 30 g, 11 ms
Shocks caused by rough handling (Drop test) 1 m
Parameter Conditions Value
Degree of protection EN 60529 IP20
Pollution degree 2
Overvoltage category III