Technical Data
User manual 9000-41011-0200000_hdb_en_20 62 / 92
Fig. 4-21: Temperature derating
Ws System width
∑I Total current
NA Not allowed
4.7.2.2 Mechanical
4.7.2.3 Electrical safety
4.7.2.4 EMC-interference
Parameter Conditions Value
Vibration test IEC 60068-2-6:2007 Test
Fc;
EN 60068-2-6:2008
sin 5 ... 17.8 Hz: 1.6
mm;
17.8 ... 500 Hz: 2.3 g
10x f
Shock test IEC 60068-2-27:2008 Test
Ea;
EN 60068-2-27:2009
1/2 sin 30 g, 11 ms
Shocks caused by rough handling (Drop test) 1 m
Parameter Conditions Value
Degree of protection EN 60529 IP20
Pollution degree 2
Overvoltage category III
Insulation voltage
input-output
Type testing / routine check
test
50 V
Parameter Conditions Value
Radio interference field strength
housing
EN 61000-6-3 Industrial and residual areas
Conducted emission
DC inputs and outputs
EN 61000-6-3 Industrial and residual areas