7 Troubleshooting VJ-1624/1624W OPERATION MANUAL
7-12
24 [****] Change Plug Time to replace Connector
rubber of High-capacity ink
pack adapter.
(VJ-1624 only)
Replace Connector rubber.
High-capacity ink
pack adapter Operation
Manual "3.2 Replacing
Connector Rubber"
25 No connector cap. Connector cap is off the
connector.
(VJ-1624 only)
Install Connector cap to the
connector of
Spectrophotometer on Print
head.
4.5 Using
Spectrophotometer (VJ-
1624 only)
26 Measurement Error
(Take Up Roll)
Media ejection mode is set to
"Take-up".
(VJ-1624 only)
Change the setting to "Off".
5.1.6 Output Mode
menu
27 Measurement Error
(Media detection)
The Media detection menu is
set to "Off".
(VJ-1624 only)
Change the setting to either
"Width" or "Top&Width".
5.1.4 Media Initial
menu
28 Measurement Error
(Media width)
The width of the media
installed does not match the
color target to be measured.
(VJ-1624 only)
Remove the media currently
set, and set a correct color
target.
3.4 Loading media
29 Measurement Error
(Command)
The parameters of the
command sent from RIP
software are abnormal.
(VJ-1624 only)
Check the settings of color
calibration or color profiling
of the RIP software.
—
30 Measurement Error
(Media End)
The media has run out while
printing or measuring the
color target.
(VJ-1624 only)
Load new media and start
printing and measuring the
color target again.
4.5 Using
Spectrophotometer (VJ-
1624 only)
31 Measurement Error
(Cover Open)
Cover(s) opened while
measuring the color target.
(VJ-1624 only)
Close Front cover and
Maintenance covers on both
sides of the printer.
3.4 Loading media
6.2.4 Cleaning
Cleaning wiper
32 Measurement Error
(Lever Lifted)
Media loading lever is raised
while printing or measuring
the color target.
(VJ-1624 only)
Printing or measuring is
cancelled. Start printing and
measuring the color target
again.
4.5 Using
Spectrophotometer (VJ-
1624 only)
33 Measurement Error
(Communication)
A communication error
occurred while printing or
measuring the color target.
(VJ-1624 only)
Check the communication
requirements between the
printer and your PC.
3.7 Connecting the
printer to PC
34 Measurement Error
(Instrument)
A communication error with
Spectrophotometer
(SPECTROVUE VM-10)
occurred while measuring the
color target.
(VJ-1624 only)
Check the connection
between the printer and
Spectrophotometer
(SPECTROVUE VM-10).
4.5 Using
Spectrophotometer (VJ-
1624 only)
35 Measurement Error
(Cancelled)
Printing or measuring the
color target has been
cancelled from Operation
panel or the RIP software.
(VJ-1624 only)
Start printing and measuring
the color target again.
4.5 Using
Spectrophotometer (VJ-
1624 only)
No. Display Description Remedy Reference