With the ACTHOR 9s, a selection of the load outputs to be used in the Legionella program can be
made in the web interface. All three outputs are activated in the factory.
TIP: If, for example, 3 single-phase heating elements are used and only one of them
is in a drinking water storage tank, then the Legionella programme should only be
used on this heating element!
In this section the choice of the signal source for the AC•THOR is made.
A control type can only be selected if the AC•THOR has the factory preset device number 1.
See "Basic settings".
The "Interval target value" function causes the AC•THOR to automatically change the target
value of the control to another adjustable target value for a certain duration in an adjustable time
interval. This can ensure that other applications with regulated surplus control are not deprived of
surplus energy by the my-PV application.