AC•THOR
®
/ AC•THOR
®
9s Operating instructions, version a0020806 40
EV Charging station power
If the "Interval target value" control function is used (see chapter "Control settings") and the "EV
Charging station power" measuring point is also queried, it is possible to define an additional
duration of the interval target value here. The interval target value is thus extended by this
additional duration, provided the power at the charging station is at least above 500W at the end of
the first interval.
The positive effect of this is that the time of the higher target value of the control can be
significantly shortened. It is regulated back to the original target value more quickly, which in turn
ensures higher self-consumption.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the my-PV AC-THOR and is the answer not in the manual?

my-PV AC-THOR Specifications

General IconGeneral
Power Range0-3 kW
Input Voltage230 V
Frequency50/60 Hz
CategoryController
Operating Temperature-25°C to +60°C
CommunicationEthernet, Modbus
Phases1-phase
Output Power0-3 kW
TypeAC-THOR