AC•THOR
®
/ AC•THOR
®
9s Operating instructions, version a0020806 48
Start power firmware update: if a newer output unit software version is present on the SD card, the
update can be started manually. After the update, the unit will be restarted automatically. With
AC•THOR 9s the update for both power stages is started.
This possibility is provided for installations without Internet access. Consultation with our technical
support is necessary. To do this, send us the 16-digit serial number to support@my-pv.com.
Never remove the SD card while the unit is operational!
Never exchange an SD card between one unit and another! It contains data specific to the
serial number of the unit.
AC•THOR: 0….. Off
1-8… Unit start-up
9… Operation
>=200 Fault conditions power stage
AC•THOR 9s: 0-15 … internal states for support purposes
>=200 Error states power stage 9s
Sensor assignment:
Operaton
mode
M1
M2
M3
M4
M5
M6
M7
Load
priority
1-2-3
3-2-1
1-2-3
1-2-3
1-2-3
3-2-1
3-2-1
1-2-3
OUT-3
Sensor 1
Sensor 1
Sensor 1
Sensor 1
Sensor 1
Sensor 1
HW
Sensor 3
SH3
Sensor 1
OUT-2
Sensor 1
Sensor 2
Sensor 1
Sensor 1
Sensor 1
Sensor 3
SH2
Sensor 2
SH2
Sensor 1
OUT-1
Sensor 1
Sensor 3
Sensor 1
Sensor 1
Sensor 1
Sensor 2
SH1
Sensor 1
SH1
Sensor 1
Sensor function:
Operating mode
M1
M2
M3
M4
M5
M6
M7
Load priority
1-2-3
3-2-1
1-2-3
1-2-3
1-2-3
3-2-1
3-2-1
1-2-3
Sensor 1
Max / Min
Max / Min
Switch-
over
Max / Min
Max / Min
Max / Min
Max / Min
Max
Sensor 2
none
Max / Min
none
none
none
Max / Min
Max / Min
PWM
Sensor 3
none
Max / Min
none
none
none
Max / Min
Max / Min
Min
Broken probe
85° Data disruption temperature sensor

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the my-PV AC-THOR and is the answer not in the manual?

my-PV AC-THOR Specifications

General IconGeneral
Power Range0-3 kW
Input Voltage230 V
Frequency50/60 Hz
CategoryController
Operating Temperature-25°C to +60°C
CommunicationEthernet, Modbus
Phases1-phase
Output Power0-3 kW
TypeAC-THOR