5 HARD START AND NO START DIAGNOSTICS 189
Figure 227 ICP Test Kit
1. ICP sen sor adapter
2. Fitting, 13/16-16 NPT
Figure 228 High-pressure oil hose assembly
1. High-pressure hose
2. Fitting, 13/16-16 NPT
3. ICP sen sor adapter
4. ICP sensor
1. Make test hose assembly with the following
components:
ICP sensor adapter
High-pressure hose (Part No. - 1842571C91
or equivalent)
VT 365 ICP sensor (Part No. - 1845274C92
or equivalent)
NOTE: The mechanic is expected to ke ep the
spare ICP sensor and high-pressure hose for
future diagnostics. Expense the spare ICP sensor
and high-pressure hose as essential tools and
keep both with other diagnostic tools. Warranty
will not cover the cost of the spare ICP sensor
and high-pressure hose.
Figure 229 High-pressure pump tting
2. Disconnect high-pressure oil hose from
high-pressure pump tting.
NOTE: Oil will spill from hose. Position the
high-pressu re oil hose so oil w ill not spill.