7167 Owner’s Manual Chapter 6: Commands
November 2003
229
Transmission Format FS ( g pL pH fn m (When fn = 60)
This command sets the transmission file format as binary or hexadecimal
ASCII FS ( g pL pH fn m
Hex 1C 28 67 pL pH fn m
Decimal 28 40 103 pL pH fn m
Range (pL + pH x 256) = 2 (pL =2, pH = 0)
fn = 60
m = 48, 49
Default m = 48
m Transmission Method
48 Transmits the image data in Binary format.
49 Transmits the image data with Hexadecimal character strings format.
Notes Since the default value of this command is set to the one most suitable for the
kind of interface, it is recommended to use the default as is. The default value can be
checked with function 100.
With the serial interface model, when XON/OFF control is selected, specify m = 49.