7167 Owner’s Manual Chapter 6: Commands
November 2003
233
Transmits the cropping area FS ( g pL pH fn m (when fn = 97)
Command Description:
The cropping area of the scanned image as defined is communicated to the host
ASCII FS ( g pL pH fn m
Hex 1C 28 67 pL pH fn m
Decimal 28 40 103 pL pH fn m
Range (pL + pH x 256) = 2 (pL =2, pH = 0)
fn = 97
m = 48
Transmission Data Hexadecimal Decima
l
Amount of Data
Header 37H 55 1 byte
Identifier 75H 117 1 byte
Fixed Value 40H, last Block
41H next Blk
exist
64 or
65
1 byte
Separator 1FH 31 1 byte
Data 30H - 39H
and 1FH
48 – 57
and 31
9 - 80 bytes
NUL 00H 0 1 Byte
The “Data” will consist of data groups enumerated with the associated key codes.
If the total amount of data exceeds 80 bytes when several cropping areas are set, the data is divided
up to a maximum of 80 bytes, then transmitted.
Transmission Data Hexadecimal Decimal Amount of Data
n of Function 57 30H - 39H 48 - 57 1-2 byte
Separator 1FH 31 1 byte
x1 of Function 57 30H - 39H 48 - 57 1 - 3 bytes
Separator 1FH 31 1 byte
y1 of Function 57 30H - 39H 48 - 57 1 - 3 bytes
Separator 1FH 31 1 byte
x2 of Function 57 30H - 39H 48 - 57 1 - 3 bytes
Separator 1FH 31 1 byte
y2 of Function 57 30H - 39H 48 - 57 1 - 3 bytes
Separator 1FH 31 1 byte