7167 Owner’s Manual Chapter 6: Commands
November 2003
236
Select Scanning mode FS ( g pL pH fn m (when fn = 101)
Command Description:
This command selects the scanning mode.
ASCII FS ( g pL pH fn m
Hex 1C 28 67 pL pH fn m
Decimal 28 40 103 pL pH fn m
Range (pL + pH x 256) = 2 (pL =2, pH = 0)
fn = 101
m = 48,49
Default m = 48
m Scanning Mode
48 Black / White mode
49 8 bit gray scale mode
Transmits Scanning mode FS ( g pL pH fn m (when fn = 102)
Command Description:
This command transmits the scanning mode.
ASCII FS ( g pL pH fn
Hex 1C 28 67 pL pH fn
Decimal 28 40 103 pL pH fn
Range (pL + pH x 256) = 1 (pL =1, pH = 0)
fn = 102
This command transmits the scanning mode as the following format.
Transmission Data Hexadecimal Decimal Amount of Data
Header 37H 55 1 byte
Identifier 3AH 62 1 byte
Fixed Value 34H, 38H 52, 56 2 bytes
Separator 1FH 31 1 byte
m of Function 101 34H, 38H or
34H, 39H
52, 56 or
52, 57
2 bytes
NUL 00H 0 1 Byte
The transmission data values are converted to hexadecimal characters strings for the image data.
Example: When data is 48 the transmission data will be:
Hexadecimal: 34H, 38H
Decimal: 52, 56
Executes Scan GS ( G pL pH fn nl nH m1 m2 [d1…dk] (when fn = 65)
Command Description: