7167 Owner’s Manual Chapter 6: Commands
November 2003
247
Notes:
• While writing flash ROM, the printer does not process a real-time command or send ASB status.
Therefore it is not possible to determine the printer status while storing scan image.
Clear All Scan Images GS ( G pL pH fn (when fn = 71)
Hogan makes busy status in clearing flash ROM. Host can’t send any data to Hogan at that time.
Command Description:
• Erase all scan image files
ASCII FS ( g pL pH fn
Hex 1D 28 47 pL pH fn
Decimal 29 40 71 pL pH fn
Range
pL=1, pH=0
fn = 71
Notes:
• While clearing flash ROM, the printer does not process a real-time command or send ASB
status. Therefore it is not possible to determine the printer status while clearing image files.
• This command sent the information block to host PC. The format is same format of the store to
flash ROM command.