6-6 Chapter 6: Touch Screen Calibration – Windows
Calibration Procedures
Note: Inordertoachieveanaccuratecalibrationthetouchdisplaymustinthe
normaloperatingpositionwhenACpowerisappliedtotheterminal(45degreescan
beassumedifthisnotknown).IfthiswasNOTdoneproperlythenbeginwithStep1.
OtherwiseskiptoStep2.
1. Disconnectth
epowercordfromthepowersource,ifpossible.Itisbesttoremove
theACpowerfromthewalloutlettoavoidhavingtomovethehead.
Waitatleast10seconds.Then,whilekeepingtheheadinthenormaloperating
positionandyourhandsoffoftheglassandbezel
,plugthecordbackin.Thehead
canbetouchedormovedafterACpowerhasbeenappliedforatleasttwo
seconds.
2. SelectStart>Programs>Microchip TSHARC Control Panel.
3. SelecttheCalibrationTab.
4. Select9Pointw/Linearization.
5. SelecttheBeginLinearizationbutton.