EasyManua.ls Logo

NCR RealPOS 70 - Touch Screen Calibration Flow Chart

NCR RealPOS 70
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 3: Touch Screen Calibration – Windows (MT 7.12) 3-13
Calibration Flow Chart
Thefollowingflowchartshowsthepropersequencetoperformthe
variouscalibrationprocedures.
25413
Note: When you re-image the hard drive, you may
get the following error message:
Controller's internal linearity data differs from its
last saved linearity data.
Do you want to use the internal linearity data?
ALWAYS choose YES
No
Yes
No
Yes
Perform 3-Point Calibration
Stop
Perform Cursor Stabilization
Yes No
Perform Restore Defaults
1st Time
Hardware needs
Servicing
Perform 3-Point Calibration
Perform 25-Point Linearization
Perform 3-Point Calibration
Stop
Stop
2nd Time
Is Calibration Correct?
(Test by touching all 4 corners
and the edges of the screen.)
Is Calibration Correct?
(Test by touching all 4 corners
and the edges of the screen.)
Is Calibration Correct?
(Test by touching all 4 corners
and the edges of the screen.)

Table of Contents

Related product manuals