6-114 Reflashing the Printer Firmware
/WIFIWireless Interface.
/HIDOnly for K8 printers.
/NHPIOnly for 7199 printers.
/PRTROnly for 7199 printers.
[parameter] --> Selections for interface parameter (Only for RS232
and Ethernet interface):
For RS232 Only: Please key in the Baud Rate, Parity and Stop
Bit
- Baud Rate Selection:
/[115200] | [57600] | [38400] | [19200] | [9600]
- Parity Selection:
/[none] | [even] | [odd]
- Stop Bit Selection:
/[1] | [2]
For WiFi / Ethernet Only: Please key in the IP Address
- IP Address Selection:
/[xxx.xxx.xxx.xxx]
- xxx is a number from 0 to 255
For CPMI, IBMUSB and HID is ignore
[file] --> Selections for the filename:
Any valid binary file with extension *.mfw | *.sfn | *.dfn |
*.ipl | *.lan | *.bin (Only for K8) | *.tbl (Only for
SSCO6–1ST/2ST and 7199) | *.cfg (Only for 7199)
[print(opt)] --> Selections for the print (Optional Parameter):
/print___________(default) Print printer configuration form.
/noprint___ _____ Bypass printing printer configuration
form.
[status(opt)] --> Optional for Return Status (Optional Parameter):
/noretstat (default) Utility will not return status code.
/retstat _Utility will return status code.
[ErrorTimeOut(opt)] --> Failsafe: Max Time Allowed for Called Exe
(Optional Parameter):
(ONLY USED BY TseFlash.COM
/ErrorTimeOut=xxx (minimum=420) xxx is number of
Seconds - limit 3600.
Information : Please use RS232 Interface, when switching
from ION <=> NON ION
If you fail to use the correct parameters, an error message will be displayed similar to the
following error:
Error: Too few / many command line parameters!
The following is an example of a command line:
TseFlash.com /7197-5X01/6X01 /m /COM1 /115200 /none /1 SP2M0609.MFW
/noskip /print /retstat
This invokes the GUI interface shown in the next section and displays a progress bar
indicator. The same is seen if you run the program through the GUI Windows GUI
Printer Firmware Update Utility.