18
U412 = limit-stop position on axis 3. Signal to the NC to stop the movement of axis
3 in negative direction and to blink error signal LIMq-.
D412 = limit-position request cancelled.
Y413 LIM3+
U413 = limit-stop position on axis 3. Signal to the NC to stop the movement of axis
3 in positive direction and to blink error signal LIMq+.
D413 = limit-position request cancelled.
Y414 LIM2-
U414 = limit-stop position on axis 2. Signal to the NC to stop the movement of axis
2 in negative direction and to blink error signal LIMq-
D414 = limit-position request cancelled.
Y415 LIM2+
U415 = limit-stop position on axis 2. Signal to the NC to stop the movement of axis
2 in negative direction and to blink error signal LIMq-.
D415 = limit-position request cancelled.
Y416 LIM1-
U416 = limit-stop position on axis 1. Signal to the NC to stop the movement of axis
1 in positive direction and to blink error signal LIMq+.
D416 = limit-position request cancelled.
Y417 LIM1+
U417 = limit-stop position on axis 1. Signal to the NC to stop the movement of axis
Z in positive direction and to blink error signal LIMq+.
D417 = limit-position request cancelled.
Y424 LIM 5-
U424 = limit-stop position on axis 5. Signal to the NC to stop the movement of axis
5 in negative direction and to blink error signal LIMq-.
D424 = limit-position request cancelled.
Y425 LIM5+
U425 = limit-stop position on axis 5. Signal to the NC to stop the movement of axis
5 in positive direction and to blink error signal LIMq+.
D425 = limit-position request cancelled.
Y426 LIM4-
U426 = limit-stop position on axis 4. Signal to the NC to stop the movement of axis
4 in positive direction and to blink error signal LIM4-.
D426 = limit-position request cancelled.
Y427 LIM4+
U427 = limit-stop position on axis 4. Signal to the NC to stop the movement of axis
4 in positive direction and to blink error signal LIM4+.