29
number)
ERROR 32 - "<Nx" is followed by an illegal character (other than L, S or number)
ERROR 33 - relation symbol "=" is followed by an illegal character (other than L, S or
number)
ERROR 34 - relation symbol "=Nx" is followed by an illegal character (other than L, S or
number)
ERROR 35 - relation symbol ">" is followed by an illegal character (other than L, S or
number)
ERROR 36 - relation symbol ", S or number)
ERROR 36 - relation symbol ">Nx" is followed by an illegal character (other than L, S or
number)
ERROR 37 - relation symbol "<=" is followed by an illegal character (other than L, S or
number)
ERROR 38 - relation symbol "<=Nx" is followed by an illegal character (other than L, S or
number)
ERROR 39 - relation symbol ">=" is followed by an illegal character (other than L, S or
number)
ERROR 40 - relation symbol ">=Nx" is followed by an illegal character (other than L, S or
number)
ERROR 41 - illegal character behind logic OR relation "O"
ERROR 42 - illegal character behind logic XOR relation "X"
ERROR 43 - illegal occurrence of quotation mark (") in the text (not preceded by instruction
PNx, PIx or PBx
ERROR 44 - not interpreted character in the PLC program
ERROR 45 - PN, PI, PB not followed by M or E
ERROR 46 - PN, PI, PB followed by an illegal character
ERROR 47 - no terminating quotation mark (") or too long string contained in the PLC
program
ERROR 48 - PxM or PxE followed by an illegal character
ERROR 49 - erratic PARAMETER subscript (LRPnn where 0<nn<9)
ERROR 50 - "P" followed by an illegal character in instruction PRINT
ERROR 51 - "L" followed by an illegal character in instruction LOAD
ERROR 52 - "S" followed by an illegal character in instruction STORE
ERROR 53 - reference is made to a non-existing module
ERROR 54 - existing module number (re-defined module)
ERROR 55 - reserved for future development
ERROR 56 - illegal jump to an internal module (G050-G059, they can be called by the
system only)
ERROR 57 - erratic subscript in instruction "Jn" (n is other than 0, 1 or 2)
ERROR 58 - writing at an odd I/O address at Uonnn instruction
ERROR 59 - illegal instruction (direct reading of OUTPUT port, LOnn)
ERROR 60 - reference made to a non-existing I/O port (only an I/O address between I000
and I377 may be issued)
ERROR 61 - J0 and/or J1 missing from the PLC program
ERROR 62 - illegal instruction "SRInnn", writing the interpolator registers is illegal
ERROR 99 - masterless "Z" in the PLC program.