10. Turn the power off and remove the CF card from the CF slot on PZ-VM21.
CPU card
CF Slot (CN2)
CF card
PZ-VM21 PCB
Figure 4-19 Removing the CF card
11. Replace the Main-Cover and Sub-Cover.
12. Turn the system power back on.
13. When the system has completed reloading the software, the RUN LED (D1) will flash blue.
To confirm the new software version number, press the Navigation key on any display telephone to
view the system version number see Main Software Version Confirmation on page 4-9.
The existing system data in the flash memory is replaced, but the customer data (stored in the RAM)
is saved.
SL1000 ISSUE 3.0
4-12 Maintenance