Guide to Feature Programming
Program Num-
ber
Program Name Default
10-09-01 DTMF and Dial Tone Circuit Setup Resource 01 - 132 = 0 (Common)
(SL1000)
Resource 01 - 96 = 0 (Common)
(SL1100)
14-02-05 Analog Trunk Data Setup - Dial Tone Detection for Manual-
ly Accessed Trunks
1
14-02-11 Analog Trunk Data Setup - Next Trunk in Rotary if No Dial
Tone
0
21-01-04 System Options for Outgoing Calls - Dial Tone Detection
Time
5 (seconds)
21-01-05 System Options for Outgoing Calls - Disconnect Time
When Dial Tone Not Detected
0
21-01-06 System Options for Outgoing Calls - Dial Pause at First
Digit
3 (seconds)
Table 1-10 Dial Tone Detection Program Interaction
Method 14-02-05 14-02-11 Result if dial tone not present . . .
Press a line key
- or -
Dial #0 + Trunk number
0 0 Trunk hangs (does not disconnect)
0 1 Trunk hangs (does not disconnect)
1 0 Trunk drops
1 1 Trunk drops
Dial a Trunk Group code
- or -
Automatically through a feature
0 0 Trunk hangs (does not disconnect)
0 1 Trunk reroutes after time-out
1 0 Trunk drops
1 1 Trunk reroutes after time-out
Operation
Dial Tone Detection is automatic if enabled in programming.
SL1000/SL1100 ISSUE 2.0
1-190
Dial Tone Detection
D