Conditions
Room Monitor is for listening only. It does not allow for conversation between the monitoring and
monitored extensions.
An extension user cannot monitor an Attendant.
A Multiline Terminal user cannot monitor a Single Line Terminal and a Single Line Terminal cannot
monitor a Multiline Terminals.
Room Monitor for Single Line Terminals can be used with the Hotel/Motel feature.
For a Multiline Terminal, Room Monitor requires uniquely programmed function keys.
Call Arrival (CAR) Key (virtual extension) keys do not support Room Monitor Programmable
Function keys (code 39).
Default Settings
Disabled
System Availability
Terminals
Multiline Terminals and Single Line Terminals
Required Component(s)
None
Related Features
Hotel/Motel
Programmable Function Keys
Guide to Feature Programming
Program Num-
ber
Program Name Default
11-14-17 Service Code Setup (for Hotel) - Hotel Room Monitor 770
15-07-01 Programmable Function Keys Refer to Programming Manual.
20-06-01 Class of Service for Extensions All extension port = Class 1
20-13-11 Class of Service Options (Supplementary Service) -
Room Monitor, Initiating Extension
COS 01~15 = 0
20-13-12 Class of Service Options (Supplementary Service) -
Room Monitor, Extension Being Monitored
COS 01~15 = 0
20-13-55 Intercom call to room monitor 0
42-03-12 Class of Service Options (Hotel/Motel) - SLT Room
Monitor
COS 01~15 = 1
ISSUE 2.0 SL1000/SL1100