5. Dial VRS message number for watching, “001”.
6. After beep tone, record the message.
7. Press Speaker key and finish recording.
To start Watch mode
1. Press Speaker key + dial 817 + 1 at terminal.
- OR -
2. Press the Function key (
32) at Multiline Terminal and the Function key turn on Red.
- OR -
3. Watch mode time pattern 1 comes time to start.
4. Each 5 minutes interval, Watching message send to internal page group 1 and external page
group 1.
To stop Watch mode
1. Press Speaker key + dial 817 + 0 at terminal
- OR -
2. Press the red lit Function key (
32) at Multiline Terminal and the Function key turn off.
- OR -
3. Watch mode time pattern 1 comes time to stop.
Warning Message (Use Security Sensor and Warning message)
< Program >
PRG 10-03-05 for SLT. Depend on Sensor, SLT port may need to set as DoorPhone type.
PRG 11-10-47: 715; Warning message setting
PRG 11-10-48: 717; Auto Dial Setting for Security Sensor
PRG 11-12-62: 816; Security Sensor Reset
PRG 11-12-64: 819+1/0; Security Sensor Mode Start/Stop
PRG 15-07-01: Set “
33” to Function key
PRG 20-46-01: 1; Sensor mode, on
PRG 20-46-02: 1; Internal paging group, 1
PRG 20-46-03: 1; External paging group 1
PRG 20-46-04: 1; VRS message number for warning, 1
PRG 20-46-05: 999; Speed dial bin number, 999
PRG 20-46-06: 2; VRS message number for destination answer, 2
PRG 20-46-07: 30; Auto Dial Wait Timer, 30 sec
PRG 20-46-08: 3; Times of auto repeat dial, 3
PRG 20-46-09: 30; Auto dial calling time, 30 sec
PRG 20-46-10: 200; Monitored terminal number, 200
PRG 20-46-11: 30; Interval of Auto Dial, 30 sec
PRG 20-48-01: 1; Security sensor time pattern, 1
PRG 20-55-01: 60sec (default); Sensor delay timer (V1.5 or higher)
Set up Warning message
1. Press Speaker key + dial 715 at terminal.
2. Dial Security sensor number, “1”.
3. Dial Internal paging group number, “01”.
SL1000/SL1100
ISSUE 2.0
1-618
Security
S