Loading...
2. Function Key 1 indication changed to "External All Call Paging".
Function Code No.20 (External All Call Paging) is indicated.
3. Click "OK".
1. At MLT already assigned External page or BGM Key, then try to assign same function to other key,
below caution message is indicated.
If you click "OK", previous assigned key becomes no setting and new key is assigned.
2. External page and BGM Key can not be assigned to multiple keys.
Conditions
Function Key Settings:
"External All Call Paging (FC No.20)" can be set using Intuition Function Key setting. Group or
internal paging can not be set.
HW Setting Operation:
Once after PCPro DB (Data Base) is modified from Default DB, Navigation Bar shows HW Setting
Link instead of Intuition QA link. Intuition QA (Page1-3) is only available when the PCPro DB is
default state.
When open the saved data base file (*.pcp), Navigation Bar shows HW setting Link instead of
Intuition QA link.
When PCPro is connected to the system, Navigation Bar shows HW setting link.
InMail Setup:
In InMail setup screen all ports for InMail are assigned in a same group.
InMail Port or Group Number can be changed after refreshing the screen.
Voice/Signal Setup (PRG 15-02-68):
SL1100
ISSUE 2.0
1-600
PC Programming - Intuition Setup