Issue 6.0 NEC SL1100
7 - 16 SIP Trunking
6.4 SIP CODEC Trunk
Program/Item
No.
Description/
Selection
Assigned Data Comments
84-13-01
SIP Trunk CODEC
Information Basic Setup –
G.711 Audio Frame Number
1 = 10ms
2 = 20ms
3 = 30ms
4 = 40ms
Default is 2
Version 5.0 or higher: Select SIP
Profile 1-2.
Set the G.711 Audio Frame
Number.
84-13-02
SIP Trunk CODEC
Information Basic Setup –
G.711 Voice Activity
Detection Mode
0 = Disable
1 = Enable
Default is 0
Version 5.0 or higher: Select SIP
Profile 1-2.
Enable/Disable the G.711 VAD
Detection Mode.
84-13-03
SIP Trunk CODEC
Information Basic Setup –
G.711 Type
0 = A-law
1 = :-law
Default is 1
Version 5.0 or higher: Select SIP
Profile 1-2.
Define the G.711 type.
84-13-04
SIP Trunk CODEC
Information Basic Setup -
G.711 Jitter Buffer (min)
0 ~ 255ms
Default is 20
Version 5.0 or higher: Select SIP
Profile 1-2.
Set the minimum G.711 Jitter
Buffer.
84-13-05
SIP Trunk CODEC
Information Basic Setup –
G.711 Jitter Buffer (average)
0 ~ 255ms
40ms = Default is 40
Version 5.0 or higher: Select SIP
Profile 1-2.
Set the average G.711 Jitter
Buffer.