Issue 6.0 NEC SL1100
9 - 50 IP Multiline Station (SIP)
10-46-07
DR700 Server
Information Setup
– Encryption Mode
Enable or disable encryption
mode.
0 = Off
1 = On
1 = Default
X
10-46-08
DR700 Server
Information Setup
– Encryption Type
Assign the encryption type.
0 = Mode 1
Default is 0
X
10-46-09
DR700 Server
Information Setup
– One-Time
Password
Password used when Program
10-46-07 is set to ON. Assign a
character string of 10 characters or
less.
Valid Characters
(0~9, *, #)
Default Not assigned
X
10-46-10
DR700 Server
Information Setup
– Start Port
With Automatic logon the starting
port number for automatic port
allocation.
Range = (1 ~ 84)
Default = 1
X
15-05-01
IP Telephone
Terminal Basic
Data Setup –
Terminal Type
Type of IP terminal registered with
the specified extension number.
0 = NGT
1 = H.323
2 = SIP
3 = MEGACO
4 = SIP MLT
Default is 3
READ ONLY
X
15-05-02
IP Telephone
Terminal Basic
Data Setup –
Terminal MAC
Address
Allow association of a MAC
Address to an extension. When
the IP phone sends a register
message to the CPU the CPU
responds back with the extension
number associated to the MAC
address.
00.00.00.00.00.00~
FF.FF.FF.FF.FF.FF
Default is
00.00.00.00.00.00
X
15-05-07
IP Telephone
Terminal Basic
Data Setup –
Using IP Address
IP address the IP Terminal is using
for the specified extension number.
0.0.0.0~
255.255.255.255.
Default is 0.0.0.0
READ ONLY
X
15-05-15
IP Telephone
Terminal Basic
Data Setup –
CODEC Type
Assign CODEC type for IP
Terminal. If SIP SLT, use Program
84-19. If SIP MLT, use Program
84-24.
1 = Type 1
2 = Type 2
3 = Type 3
4 = Type 4
5 = Type 5
1 = Default is 1
X
15-05-20
IP Telephone
Terminal Basic
Data Setup –
Bottom Option
Information
Read Only CM showing type of
adapter installed on the ITH-style
telephone.
0 = No Option
1 = ADA
2 = BHA
Default is 0
READ ONLY
X
Program
Number
Program Name Description/Comments Assigned Data 1 2 3