Program 80 : Basic Hardware Setup for System
80-04 : Call Progress Tone Detector Setup
Level:
MF
Description
Use Program 80-04 : Call Progress Tone Detector Setup to define the various levels and timers for
the Call Progress Tone Detector.
Tone Detector Type :
1 = Dial Tone for Trunk
2 = Busy Tone for Trunk
3 = Ring Back Tone for Trunk
4 = Special Busy Tone for Trunk
5 = Special Ring Back Tone for Trunk
Input Data
Tone Detector Type Number
1 = Dial Tone for Trunk
2 = Busy Tone for Trunk
3 = Ring Back Tone for Trunk
4 = Special Busy Tone for Trunk
5 = Special Ring Back Tone for Trunk
Item
No.
Item Input Data Default
01 Detection Level 0 = 0 dBm ~ - 25 dBm
1 = - 5 dBm ~ - 30 dBm
2 = - 10 dBm ~ - 35 dBm
3 = - 15 dBm ~ - 40 dBm
4 = - 20 dBm ~ - 45 dBm
5 = - 25 dBm ~ - 50 dBm
6 = - 30 dBm ~ - 55 dBm
Refer below
02 Min. Detection Level 0 ~ 15
0 = - 10 dBm (0) ~ - 25 dBm (15)
1 = - 15 dBm (0) ~ - 30 dBm (15)
2 = - 20 dBm (0) ~ - 35 dBm (15)
3 = - 25 dBm (0) ~ - 40 dBm (15)
4 = - 30 dBm (0) ~ - 45 dBm (15)
5 = - 35 dBm (0) ~ - 50 dBm (15)
6 = - 40 dBm (0) ~ - 55 dBm (15)
Refer below
03 S/N Ratio 0 ~ 4 (0 dB ~ - 20 dB) Refer below
04 No Tone Time 0 ~ 255 (30 + 30 ~ 7680 ms)
(0 = not detect)
1 ~ 255 = 60 ~ 7680 ms
The formula is 30 + 30N
When set to N = 1, it means 30 + 30
*
1 = 60.
When set to N = 255, it means 30 + 30
*
255 =
7680.
Refer below
05 Pulse Count 1 ~ 255 Refer below
06 ON Minimum Time 1 ~ 255 (30 + 30 ~ 7680 ms) Refer below
07 ON Maximum Time 0 ~ 255 (30 + 30 ~ 7680 ms) Refer below
ISSUE 6.0 SL1100