Loading...
If the system cuts the power via the ecology feature while a user is on a call, the call will not be lost.
If the user places the caller on hold or park, the user's phone will then switch to power cutting mode
and the call will be lost.
If power cutting set “on” manually during scheduled power cutting “off” state, power cutting “on” state
continues until next power cutting “off” time.
The system does not start the cutting telephone power until next schedule.
Time schedule
Operation
0:00 6:00 19:00 19:000:00 0:006:00
0:00 6:00 19:00 19:000:00
Cancel the cutting telephone power by manual operation.
Power “off” state
Power “on” state
0:006:00
Figure 1-13 Time Schedule 1
Vice versa if power cutting is set “off” manually during scheduled power cutting “on” state, power
cutting “off” state continues to next power cutting “on” time.
The system does not start the power supply until next schedule.
Set the cutting telephone power by manual operation.
Power “off” state
Power “on” state
Time schedule
Operation
0:00 6:00 19:00 19:000:00 0:006:00
0:00 6:00 19:00 19:000:00 0:006:00
Figure 1-14 Time Schedule 2
During power cutting “off” state,
- Outgoing calls can not be made.
- Incoming calls receive a busy tone.
- Call forward features work at the forward set terminal.
- Disables Both Ring CFW / Follow Me.
Power saving mode
The system activates power saving mode when the Multiline Terminal is idle or no incoming calls are
received during the programmed time period. This darkens the brightness of all Line Key and
feature key LED's on the Multiline Terminal. This feature does not affect the display of the terminal.
Power saving mode can be set for each terminal individually.
ISSUE 1.0