Howler Tone Service
Description
Howler Tone Service provides a Howler Tone when a station remains off-hook after a call is completed
or when a station is off-hook and digits are not dialed in a programmed time.
Conditions
Howler tone is generated 30 seconds after a call is disconnected and the telephone is left off-hook or
the telephone is left off-hook without dialing.
Default Settings
Enabled
System Availability
Terminals
All Terminals
Required Component(s)
None
Related Features
None
Guide to Feature Programming
Program
No.
Program Name Input Data Default
20-18-02 Service Tone Timers - Busy Tone Timer 0 ~ 64800 seconds 15
80-01-01 Service Tone Setup - Repeat Count 0 ~ 255 (0 = Endless) Refer to the Program-
ming Manual for the
default values.
80-01-02 Service Tone Setup - Basic Tone Number 0 ~ 33
(0 = No Tone)
(33 = Default Time Slot)
Refer to the Program-
ming Manual for the
default values.