Remote Inspection
• When Remote inspection is set to the terminal, “Confirm” and “Ring time” are displayed on the
Multiline Terminal LCD.
• If Remote inspection terminal is busy (receiving another incoming call or on call state), inspection
ring will start after previous call ends.
• When the terminal does not answer inspection ringing during the time assigned in PRG 20-45-03,
emergency calls will be placed to pre-programmed destination with pre-recorded VRS message.
• After finishing VRS message, destination person can start monitoring of inspection terminal. Also by
dialing
from outside it is possible to have a two-way conversation.
If you dial
while the message is being played, this will not enable the cut through. Dialing
during
the message stops the message from being played and you must dial
again to enable two-way
speech path.
When using Analog trunks, the destination person must dial
before the initial message is played to
the caller.
• If outgoing call restriction is set, the emergency call number must be pre-registered in the restriction
allow table, then emergency call can go through. Also even all trunk are busy, the call has high
priority and can go out.
• If destination does not answer the emergency call, the system repeatedly places the call for the
number of times specified in PRG 20-45-07.
• Maximum of 6 extensions can be set as Remote Inspection terminals.
• If all VRS channels are busy, tone will be provided instead of VRS message, such as for inspection
message or for destination message.
• If VRS message itself is not recorded, tone will be provided.
Emergency call destination MUST be set considering this feature’s purpose.
• The emergency number dialed does not follow ARS settings.
If PRG 13-01-01 is set to Trunk the system uses command PRG 13-05 to route the emergency call.
If PRG 13-01-01 is set to ICM the system uses command PRG 14-06 to route the emergency call.
• The VRS allows you to record up to 100 VRS messages (001-100). If you are using the built in VRS,
without the SD card, you can record all the incoming/outgoing messages within two hours message
storage.
Emergency Call 1
Emergency calls when “Security Sensor” or “Remote Inspection” performed, SMDR can record these
call class as follows.
• Security Sensor: SAD
• Remote Inspection: WAD
Emergency Call 2
Emergency calls when “Security Sensor” or “Remote Inspection” performed, alarm report can record
these alarm and alarm display terminal indicates following on LCD.
• Security Sensor: 31: Sensor Dial
• Remote Inspection: 32: Confirm dial
Recording Emergency Call
By setting PRG 90-20-11 (1; Report), Emergency calls can be recorded on security report.
• Maximum of 50 records can be saved.
ISSUE 1.0
SL2100
Features and Specifications Manual 1-753
S