Program
No.
Program Name Input Data Default
14-04-01 Behind PBX Setup - Type of Connection 0 = Stand Alone (Trunk)
1 = Behind PBX (PBX)
3 = CTX assume 9
0
16-02-01 Department Group Assignment for Extensions 1 - 50 1
80-05-01 Date Format for SMDR and System - Date Format
Needs to be set to European Format
0 = American Format (Month /
Day / Year)
1 = Japanese Format (Year /
Month / Day)
2 = European Format (Day /
Month / Year)
2
SMDR flowcharts are located on the following pages.
Start
Connect an
Ethernet cable
from the CPU to
the PC to be used
for SMDR.
In PRG 10-20-01,
define the TCP port
when communicating
to the SMDR
(external device 5).
In PRG 35-01-01 set the
SMDR output for SMDR
port to “3” for LAN.
Go to
“A”.
Figure 1-40 SMDR with a CPU Connection Ethernet
ISSUE 1.0
SL2100
Features and Specifications Manual 1-799
S