Program
No.
Program Name Input Data Default
80-03-04 DTMF Tone Receiver Setup - Max. Detect Level 0 ~ 15
DTMF Tone 0 = 0 dBm (0) to - 15
dBm (15)
DTMF Tone 1 = - 5 dBm (0) to -
20 dBm (15)
DTMF Tone 2 = - 10 dBm (0) to -
25 dBm (15)
DTMF Tone 3 = - 15 dBm (0) to -
30 dBm (15)
DTMF Tone 4 = - 20 dBm (0) to -
35 dBm (15)
DTMF Tone 5 = - 25 dBm (0) to -
40 dBm (15)
DTMF Tone 6 = - 30 dBm (0) to -
45 dBm (15)
Refer to the Program-
ming Manual for the
default values.
80-03-05 DTMF Tone Receiver Setup - Forward Twist Level 0 ~ 9 (1 dB ~ 10 dB) Refer to the Program-
ming Manual for the
default values.
80-03-06 DTMF Tone Receiver Setup - Backward Twist
Level
0 ~ 9 (1 dB ~ 10 dB) Refer to the Program-
ming Manual for the
default values.
80-03-07 DTMF Tone Receiver Setup - ON Detect Time 1 ~ 255 (15 + 15 ms ~ 3825 ms) Refer to the Program-
ming Manual for the
default values.
80-03-08 DTMF Tone Receiver Setup - OFF Detect Time 1 ~ 255 (15 + 15 ms ~ 3825 ms) Refer to the Program-
ming Manual for the
default values.
80-04-01 Call Progress Tone Detector Setup - Detection
Level
0 = 0 dBm ~ - 25 dBm
1 = - 5 dBm ~ - 30 dBm
2 = - 10 dBm ~ - 35 dBm
3 = - 15 dBm ~ - 40 dBm
4 = - 20 dBm ~ - 45 dBm
5 = - 25 dBm ~ - 50 dBm
6 = - 30 dBm ~ - 55 dBm
Refer to the Program-
ming Manual for the
default values.
80-04-02 Call Progress Tone Detector Setup - Min. Detec-
tion Level
0 ~ 15
0 = - 10 dBm (0) ~ - 25 dBm (15)
1 = - 15 dBm (0) ~ - 30 dBm (15)
2 = - 20 dBm (0) ~ - 35 dBm (15)
3 = - 25 dBm (0) ~ - 40 dBm (15)
4 = - 30 dBm (0) ~ - 45 dBm (15)
5 = - 35 dBm (0) ~ - 50 dBm (15)
6 = - 40 dBm (0) ~ - 55 dBm (15)
Refer to the Program-
ming Manual for the
default values.
80-04-03 Call Progress Tone Detector Setup - S/N Ratio 0 ~ 4 (0 dB ~ - 20 dB) Refer to the Program-
ming Manual for the
default values.
80-04-04 Call Progress Tone Detector Setup - No Tone
Time
0 ~ 255 (30 + 30 ~ 7680 ms)
(0 = not detect)
1 ~ 255 = 60 ~ 7680 ms
The formula is 30 + 30N
When set to N = 1, it means 30
+ 30
1 = 60.
When set to N = 255, it means
30 + 30
255 = 7680.
Refer to the Program-
ming Manual for the
default values.
80-04-05 Call Progress Tone Detector Setup - Pulse Count 1 ~ 255 Refer to the Program-
ming Manual for the
default values.
80-04-06 Call Progress Tone Detector Setup - ON Mini-
mum Time
1 ~ 255 (30 + 30 ~ 7680 ms) Refer to the Program-
ming Manual for the
default values.
80-04-07 Call Progress Tone Detector Setup - ON Maxi-
mum Time
0 ~ 255 (30 + 30 ~ 7680 ms) Refer to the Program-
ming Manual for the
default values.
ISSUE 1.0 SL2100
Features and Specifications Manual 1-895