SL2100 GETTING STARTED GUIDE
36
Section 5 Connecting Extensions and Trunks
Take the following precautions when running the cables.
Do not run the cable with a power cable, computer cable etc.
Do not run the cable near any high frequency generating equipment.
Use cable protectors if the cables are run on the floor.
Aerial distribution wiring is not allowed.
Maximum cable lengths are listed in the following table.
Device
Cable Type
Cable Run Length
IP7WW-12/24TXH-B1
24AWG (
Ø
0.5 mm)
300 m
IP7WW-60DSS-B1
24AWG (
Ø
0.5 mm)
300 m
IP7WW-8IPLD-C1
Cat5/5e Straight Cable
100 m
AnalogTerminals(20mA)
24AWG (Ø0.5 mm)
1125 m