EasyManua.ls Logo

NEC SL2100 - Operator Extension

NEC SL2100
678 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program 20 : System Option Setup
20-17 : Operator Extension
Level:
IN
Description
Use Program 20-17 : Operator Extension to designate an operator. When an extension user dials 0
(defined by Program 1
1-01 Type 5), calls go to the operator selected in this program.
If you do not assign an extension in Program 90-11-01, system alarms appear on the extension
assigned in this option.
Input Data
Operator Number 1 ~ 10
Item
No.
Item Input Data Description Default Related
Program
01 Operator’s Ex-
tension Number
Up to eight digits Define the extension numbers which
are to be used by operators.
operator No.1 =
101
operator No.2 ~
10 = No Setting
11-01
20-01-01
02 Operator Con-
sole
0 = Normal Key Set
1 = Special Operator
Console
Determines an operator console
type when any extension user dials
"0"
, the assigned extensions shall
ring.
0
Conditions
None
Feature Cross Reference
Intercom
SL2100 ISSUE 2.0
2-210 Program 20 : System Option Setup
Program
20

Table of Contents

Other manuals for NEC SL2100

Related product manuals