Program 20 : System Option Setup
20-28 : Trunk to T
runk Conversation
Level:
IN
Description
Use Program 20-28 : Trunk to T
runk Conversation to define system options for Trunk to Trunk
Conversation.
Input Data
Item
No.
Item Input Data Description Default Related
Program
01 Conversation
Continue Code
0 ~ 9,
, #
(Set for one digit only)
Input the code that can be dialed to
continue the conversation after the
Trunk-to-T
runk Release Warning
Tone is heard.
No Setting 14-01-25
20-28-03
24-02-07
24-02-10
25-07-07
25-07-08
02 Conversation
Disconnect Code
0 ~ 9,
, #
(Set for one digit only)
Input the code that can be dialed to
disconnect the conversation after
the Trunk-to-T
runk Release Warning
Tone is heard.
No Setting 14-01-25
24-02-07
24-02-10
25-07-07
25-07-08
03 Conversation
Continue Time
0 ~ 64800 seconds Input how long the conversation ex-
tends when the Conversation Con-
tinue Code is dialed.
0 14-01-25
20-28-01
24-02-07
24-02-10
25-07-07
25-07-08