Item
No.
Item Input Data Description Default Related
Program
10 Dial Digits for
Toll Restriction
Path
0 ~ 24 If this option is programmed with an
entry other than 0, a call does not
have a talk path unless the user di-
als at least the number of digits en-
tered in this option when placing an
outgoing call.
This means that an entry of 4 or
higher in this program causes a
problem when dialing 911 (USA on-
ly). Since it is only a 3-digit number
,
the call does not have a talk path,
preventing the emergency dispatch-
er from hearing the caller. This op-
tion should be kept at its default set-
ting of 0 to prevent any problems
with dialing 911 (USA only).
0
11 Inter-Digit Time
for Toll Restric-
tion Path Control
0 ~ 60 seconds 0
12 Dial E911 Rout-
ing Without
Trunk Access
0 = Trunk Access Code
Required
1 = Trunk Access Code
Not Required
If enabled (1), an extension user
can dial 911 (USA only) without first
dialing a trunk access code or
pressing a line key. If disabled (0),
an extension user must dial a trunk
access code (e.g., 9) or press a line
key before dialing 911 (USA only).
1
13 Alarm Ring Tim-
er (E911)
0, 1~ 64800 seconds
(0 = Off)
Use this option to set the duration of
the E911 Alarm Ring Time. If set for
0, the E911 Alarm does not ring.
0 11-12-56
20-08-16
14 Forced Account
Code Inter-digit
Timer
0 ~ 64800 seconds If the user does not enter the ac-
count code in the amount of time
specified in this program the call will
be restricted.
3
15 Outgoing Disable
on Incoming Line
(Toll Restriction)
0 = Disable (Off)
1 = Enable (On)
Enable or disable the Outgoing Dis-
able on Incoming Line feature.
0 15-01-05
21-01-16
21-01-17
80-03-01
16 Supervise Dial
Detection Timer
0 ~ 64800 seconds With the Outgoing Disable on In-
coming Line feature, if dial tone is
not detected after the extension an-
swers an incoming line, the system
determines the call is unable to
complete and releases the DTMF
receiver.
20 15-01-05
21-01-16
21-01-17
80-03-01
17 Restriction Digit
in Outgoing Dis-
able on Incoming
Line
Digits 1 ~ 9 With the Outgoing Disable on In-
coming Line feature, determine the
number of digits to be dialed before
the call should be disconnected.
4 15-01-05
21-01-15
21-01-16
80-03-01
18 Reset Dial After
Failure of Trunk
Access
0 = Disable (Off)
1 = Enable (On)
Enable (1) or Disable (0) the ability
to continue to dial codes or exten-
sions after receiving Trunk Busy.
This needs to be set to Enabled (1)
for the Forced Trunk Disconnect
feature to work.
1
19 Do-Not-Call-Set-
up
0 = No service
1 = Extented common
restriction
0 15-01-07
20 Caller ID Call-
back with Home
Area Code Mode
0 = Disable
1 = Manual Call Back
2 = Automatic Call
Back
0 = Disable
1 = CID Call Back is manual
2 = Call Back is automatic based on
the entries of the Home NPA, HNPA
Exceptions, and Foreign NPA Locals
0 21-01-21
21-01-22
21-26-01
21-27-01
21-28-01
ISSUE 2.0 SL2100
Programming Manual 2-257
Program
21