Item
No.
Item Input Data Description Default Related
Program
09 Two B-Channel
Transfer Retry
T
imer
1 ~ 30 seconds 10 10-03-16
(PRI)
10 Disconnect
Trunk-to-Trunk
0 ~ 64800 seconds 0 14-01-25
20-28-01
20-28-02
20-28-03
24-02-07
11 No Answer Step
Transfer
0 ~ 64800 seconds
10 14-01-26
12 No Answer
Trunk-to-Trunk
Transfer
0 ~ 64800 seconds 0 14-01-26
13 Hook Flash
Sending Timer
When the Sys-
tem Answers Au-
tomatically
0 ~ 64800 seconds
Time before sending the hook flash
for Call Forward Centrex.
2
15 SIP Out of Range
Timer
0 ~ 30 seconds
When not receiving any response
within this timer setting, the system
determines that the SIP terminal is
out of range. When set to 0, timer is
invalid.
4
Conditions
None