Item
No.
Item Input Data Description Default Related
Program
09 DISA Internal
Paging Time
0 ~ 64800 seconds
This is the maximum length of an In-
ternal Page placed by a DISA caller.
If the Page continues longer than
this time, the system terminates the
DISA call.
30 seconds 20-31-21
10 DISA External
Paging Time
0 ~ 64800 seconds This is the maximum length of an
External Page placed by a DISA
caller. If the Page continues longer
than this time, the system termi-
nates the DISA call.
30 seconds 20-31-22
11 VRS/DISA An-
swer Delay Time
0 ~ 64800 seconds Sets up the time the system waits
after receiving an incoming VRS/
DISA call before the system auto-
matically answers the call.
0 second
13 VRS/DISA Busy
Tone Interval
0 ~ 64800 seconds If a DISA caller dials a busy exten-
sion (and Program 25-04 = 0), the
system plays busy tone for this time
before disconnecting.
5 seconds
14 Delayed VRS An-
swer Time
0 ~ 64800 seconds
Assign the delay time from switching
from a normal incoming status to
DID mode. If this time is set to 0, the
call switches to DID mode immedi-
ately.
10 seconds
Conditions
None
Feature Cross Reference
Direct Inward System Access (DISA)
SL2100 ISSUE 2.0
2-328 Program 25 : VRS/DISA Setup