EasyManua.ls Logo

NEC SL2100 - Program 32: Door Box and Sensor Setup; Door Box Timers Setup

NEC SL2100
678 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program 32 : Door Box and Sensor Setup
32-01 : Door Box Timers Setup
Level:
IN
Description
Use Program 32-01 : Door Box Timers Setup
to assign the timers used for the Door Box.
The Door Box feature is called Door Phone when programming via WebPro and using a multiline terminal.
Input Data
Item
No.
Item Input Data Description Default
01 Door Box Answer
Time
0 ~ 64800 seconds
A user can answer the door box during the
time specified in this program.
30 seconds
02 Door Lock Cancel
Time
0 ~ 64800 seconds When a user activates the door lock re-
lease relay, this program specifies the
amount of time the door strike remains
open.
10 seconds
03 Off-Premise Call For-
ward by Door Box
Disconnect Timer
0 ~ 64800 seconds Define the conversation period for an Off-
Premise Call Forward by Door Box call.
When this timer expires, the caller hears
busy tone for three seconds (fixed time),
and the call is then disconnected.
60 seconds
Conditions
None
Feature Cross Reference
Door Box
SL2100 ISSUE 2.0
2-364 Program 32 : Door Box and Sensor Setup
Program
32

Table of Contents

Other manuals for NEC SL2100