Item
No.
Item Input Data Default
20 Ringing Signal Stop Detection
Time (OPX)
1 ~ 255 (100 ms ~ 25500 ms) 50 (5000 ms)
21 Loop Current Detection T
ime
(Loop)
1 ~ 250 (4 ms ~ 1000 ms) 40 (160 ms)
22 Loop Current Detection Time
(Ground)
1 ~ 250 (4 ms ~ 1000 ms) 40 (160 ms)
23 Loop Current Detection Time (DID) 1 ~ 250 (4 ms ~ 1000 ms) 40 (160 ms)
24 Loop Current Detection Time
(E&M)
1 ~ 250 (4 ms ~ 1000 ms) 40 (160 ms)
25 Loop Current Detection Time
(OPX)
1 ~ 250 (4 ms ~ 1000 ms) 40 (160 ms)
26 DP Break Send Time (ALL) 1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)
27 DP Make Send Time (ALL) 1 ~ 250 (4 ms ~ 1000 ms) 10 (40 ms)
28 DP InterDigit Send Time (ALL) 1 ~ 255 (100 ms ~ 25500 ms) 7 (700 ms)
29 HookFlash Send Time (Loop) 1 ~ 255 (100 ms ~ 25500 ms) 5 (500 ms)
30 HookFlash Send Time (Ground) 1 ~ 255 (100 ms ~ 25500 ms) 5 (500 ms)
31 HookFlash Send Time (DID) 1 ~ 255 (100 ms ~ 25500 ms) 5 (500 ms)
32 HookFlash Send Time (E&M) 1 ~ 255 (100 ms ~ 25500 ms) 5 (500 ms)
33 HookFlash Send Time (OPX) 1 ~ 255 (100 ms ~ 25500 ms) 5 (500 ms)
34 Pause Send Time (ALL) 1 ~ 255 (1 sec ~ 255 sec ) 3 (3 sec)
35 Wink Send Duration Time (DID) 1 ~ 250 (8 ms ~ 2000 ms) 25 (200 ms)
36 Delay Send Duration Time (DID) 1 ~ 250 (8 ms ~ 2000 ms) 25 (200 ms)
37 Incoming-Wink Send Time (DID) 1 ~ 255 (100 ms ~ 25500 ms) 3 (300 ms)
38 Wink Send Duration Time (E&M) 1 ~ 250 (8 ms ~ 2000 ms) 25 (200 ms)
39 Delay Send Duration Time (E&M) 1 ~ 250 (8 ms ~ 2000 ms) 25 (200 ms)
40 Incoming-Wink Send Time (E&M) 1 ~ 255 (100 ms ~ 25500 ms) 3 (300 ms)
41 Seizure-WINK/DELAY Receive Max.
Time (DID)
1 ~ 255 (100 ms ~ 25500 ms) 48 (4800 ms)
42 Receive W
ink Duration Min. Time
(DID)
1 ~ 250 (8 ms ~ 2000 ms) 12 (96 ms)
43 Receive Wink Duration Max. Time
(DID)
1 ~ 250 (8 ms ~ 2000 ms) 45 (360 ms)
44 Seizure-WINK/DELAY Receive Max.
Time (E&M)
1 ~ 255 (100 ms ~ 25500 ms) 48 (4800 ms)
45 Receive Wink Duration Min. Time
(E&M)
1 ~ 250 (8 ms ~ 2000 ms) 12 (96 ms)
46 Receive Wink Duration Max. Time
(E&M)
1 ~ 250 (8 ms ~ 2000 ms) 45 (360 ms)
47 Receive DP Make Min. Time (ALL) 1 ~ 250 (4 ms ~ 1000 ms) 3 (12 ms)
48 Receive DP Make Max. Time (ALL) 1 ~ 250 (4 ms ~ 1000 ms) 19 (76 ms)
49 Receive DP Break Min. Time (ALL) 1 ~ 250 (4 ms ~ 1000 ms) 3 (12 ms)
50 Receive DP Break Max. Time (ALL) 1 ~ 250 (4 ms ~ 1000 ms) 25 (100 ms)
51 Receive DP InterDigit Min. Time
(ALL)
1 ~ 250 (4 ms ~ 1000 ms) 125 (500 ms)
52 Receive HookFlash Duration Min.
Time (E&M)
1 ~ 255 (100 ms ~ 25500 ms) 3 (300 ms)
53 Receive HookFlash Duration Max.
Time (E&M)
1 ~ 255 (100 ms ~ 25500 ms) 6 (600 ms)
SL2100 ISSUE 2.0