Program 82 : Basic Hardware Setup for
Extension
82-04 : SLIU Initial Data Setup
Level:
MF
Description
Use Program 82-04 : SLIU Initial Data Setup to set the basic data of the SL
T.
Input Data
Item
No.
Item Input Data Default
01 Companding Method Type 0 = μ-law
1 = A-law
0
02 Ringing Frequency 0 = 25 Hz
1 = 20 Hz
2 = 16 Hz
1 (20 Hz)
03 Minimum Break Time 1 ~ 255 (5 ms ~ 1275 ms) 2 (10 ms)
04 Maximum Break Time 1 ~ 255 (5 ms ~ 1275 ms) 20 (100 ms)
05 Minimum Make Time 1 ~ 255 (5 ms ~ 1275 ms) 2 (10 ms)
06 Maximum Make Time 1 ~ 255 (5 ms ~ 1275 ms) 20 (100 ms)
07 Minimum Hook Flash Time 1 ~ 255 (5 ms ~ 1275 ms) 21 (105 ms)
08 Maximum Hook Flash Time 1 ~ 255 (5 ms ~ 1275 ms) 132 (660 ms)
09 Minimum Ground Flash Time 1 ~ 255 (5 ms ~ 1275 ms) 21 (105 ms)
10 Minimum Off-Hook Time 1 ~ 255 (5 ms ~ 1275 ms) 21 (105 ms)
11 No Detection Time after Off-Hook 1 ~ 255 (5 ms ~ 1275 ms) 60 (300 ms)
12 No Detection Time after Pulse Dial
Detection
1 ~ 255 (5 ms ~ 1275 ms) 70 (350 ms)
13 Loop Disconnect Time, Reversal
Time
1 ~ 255 (10 ms ~ 2550 ms) 60 (600 ms)
14 Ring, Message W
ait Period Time 1 ~ 255 (5 ms ~ 1275 ms) 150 (750 ms)
15 Door Phone button ON time 1 ~ 255 (5ms ~ 1275 ms) 50 (250 ms)
16 Door Phone button OFF time 1 ~ 255 (5ms ~ 1275 ms) 20 (100 ms)
Conditions
None
Feature Cross Reference
None
ISSUE 2.0 SL2100
Programming Manual 2-519
Program
82

Table of Contents

Other manuals for NEC SL2100