Loading...
Alarm
No.
Name
Item
No.01
de-
fault
Item
No.02
de-
fault
Content of
alarm
< generation
timing >
Cause Measures Recovery
Alarm
Status
10 ISDN Link
Error
0 0 Layer1 link of
ISDN lines
came off.
<Operate it >
Connected deter-
mination of main
device and ISDN
line.
Breakdown of
DSU.
The setting of
PRG10-03 is not
corresponding to
an actual line.
Confirm the data of
PRG10-03.
Reconfirm wiring
and the installation
of DSU.
Please inquire of
the manufacturer
when the problem
occurs after it con-
firms it.
When the
connection
returns nor-
mally, the
error is re-
covered.
ERR
REC
11 CTI Link
Error
0 0 The link with
the CTI server
came off.
<Operate it >
LAN cable cuts
it.
Connected HUB
broke.
The CTI server
doesn't start nor-
mally.
Please reconfirm
the CTI server, wir-
ing, and the con-
nection.
Please inquire of
the manufacturer
when the problem
occurs after it con-
firms it.
When the
connection
returns nor-
mally, the
error is re-
covered.
ERR
REC
12 ACD MIS
Link Error
0 0 The link with
ACD MIS client
PC came off.
<Operate it >
LAN cable cuts
it.
Connected HUB
broke.
ACD MIS client
PC doesn't start
normally.
Please confirm
ACD MIS client PC
and connected
part.
Please inquire of
the manufacturer
when the problem
occurs after it con-
firms it.
When the
connection
returns nor-
mally, the
error is re-
covered.
ERR
REC
13 Charge
manage-
ment link
error
0 0 The link with
the charge
management
device came
off.
<Operate it >
1. Problem of wir-
ing to connect
main device
with charge
management
device.
2. Problem of
PC.
1. It is confirmed
that there is no
problem in wir-
ing to connect
a main device
with the
charge man-
agement de-
vice. (Whether
ping passes
for LAN con-
nection is con-
firmed.)
2. Restart the
charge man-
agement soft-
ware.
3. Reboot PC,
and start the
charge man-
agement soft-
ware.
When the
connection
returns nor-
mally, the
error is re-
covered.
ERR
REC
14 LAN Link
Error
0 0 The link with
LAN on CPU
came off.
<Operate it >
LAN cable cuts
it.
Connected HUB
broke.
Defect of CPU.
Confirm the opera-
tion of LAN con-
nector, LAN cable,
and HUB again.
When the
connection
returns nor-
mally, the
error is re-
covered.
ERR
REC
SL2100 ISSUE 2.0
2-584 Program 90 : Maintenance Program