Alarm
No.
Name
Item
No.01
de-
fault
Item
No.02
de-
fault
Content of
alarm
< generation
timing >
Cause Measures Recovery
Alarm
Status
29 Charge
manage-
ment buffer
full
0 0 The temporary
buffer for the
charge man-
agement in
main device
was overflow
,
and a part of
unoutput
charge data
disappeared
because it was
not able to out-
put the charge
management
data.
<Operate it >
1. The charge
data is printed
and not de-
leted at the
simple charge
management.
2. The charge
data is not out-
put to PC for
the charge
management
software.
1. Please print
and delete the
charge data at
the simple
charge man-
agement.
2. Please con-
nect the
charge man-
agement soft-
ware for the
charge man-
agement soft-
ware and out-
put the charge
data.
When the
output is re-
started, the
error is re-
covered.
However,
the charge
manage-
ment data
after the er-
ror occurs is
not recor-
ded.
ERR
REC
30 SMDR buf-
fer full
2 0 The temporary
buffer for
SMDR in main
device was
overflow, and a
part of unoutput
SMDR data
disappeared
because it was
not able to out-
put SMDR da-
ta.
<Operate it >
1. Problem of wir-
ing to connect
main device
with PC.
2. Problem of
PC.
1. Please confirm
whether there
is problem in
wiring to con-
nect a main
device with
PC.
2. Please exe-
cute the reacti-
vation of PC.
When the
output is re-
started, the
error is re-
covered.
However,
the SMDR
data after
the error oc-
curs is not
recorded.
ERR
REC
31 Sensor Au-
to Dial
1 0 INF
32 Confirm Di-
al NoAns
1 0 INF
33 Reserved 1 0
34 Reserved 0 0
35 Reserved 0 0
36 Reserved 0 0
37 Reserved 0 0
38 Reserved 0 0
39 Reserved 0 0
40 Reserved 0 0
41 License
Name File
Load error
1 0 Can’t show Li-
cense Name,
because Sys-
tem fails to load
license name
file with system
boot up.
License Name File
is broken or file for-
mat is invalid.
Execute
PRG90-04-03 after
copy valid license
name file to SD
Card again.
Canceled
after valid li-
cense name
file is loa-
ded.
ERR
REC
42 4W termi-
nals does
not start
up.
2 0 308U or 008U
(WW) install to
Slot-4.
308U or 008U
(WW) install to
Slot-4.
Especially, anything
need not be done.
INF
43 2W termi-
nals does
not start
up.
2 0 082U install to
Slot-4.
082U install to
Slot-4.
Especially, anything
need not be done.
INF
44 Reserved 2 0
45 Reserved 0 0