Wall Mount the SL2100 System
Quick Install Guide – SL2100 with ISDN PRI Trunks rev 1.1 17
4b- Rack Mount the SL2100 system
Installation Considerations:
If the system requires two or three chassis then each chassis will require a shelf plate within the 19 inch
rack, must be space above each chassis for heat ventilation.
Do not stack two or three chassis per one shelf plate.
3U space will be required for each KSU.
Rack mount shelf requires 448mm x 337mm x 100mm (W x D x H) within the rack.
The AC power cable enters at the rear of the chassis, allow ~60mm for space at the
rear.
Ventilation is required above the chassis.
You may need to connect the AC power cable and Earth Ground cable to the rear of
the chassis prior to installing into the rack if you do not have sufficient space/access
to do this afterwards.