EasyManua.ls Logo

NEC UNIVERGE SV8500 - A both TSW Failure (Permanent)

NEC UNIVERGE SV8500
975 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 217 –
CHAPTER 3 System Messages
1-A: Both TSW Failure (Permanent)
This message displays when link information cannot be written into the switch memory of the TSW in both
systems.
TSW system in which a fault is
detected
Status at the time of fault detection
Data Analyzed by NEC Engineers
Reference: See section 4.5.3 on page 633, for the repair procedure.
Default Alarm Default Grade Grade Modified Lamp Modified
MN 3
1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
b7 b0
b7 b6 b0
1 2
3
b0: 0/1 = TSW 0/TSW 1
1
b0: 0/1 = TSW System 0/TSW System 1
b6: Speech Path in ACT status
0/1 = System 0/System 1
2
3

Table of Contents

Other manuals for NEC UNIVERGE SV8500

Related product manuals