EasyManua.ls Logo

NEC Univerge SV9100 - Page 236

NEC Univerge SV9100
954 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 4.0
2-196 Program 15 : Extension, Basic Setup
06
Extension Polarity Reverse
Not Used in U.S. --
Do Not Change Default Entry as DTMF issues
may arise with voice mail.
0 = Disable (Off)
1 = Enable (On)
0
07
Enabled On-Hook When Holding (SLT)
0 = No
1 = Yes
1 11-12-45
08
Answer On-Hook when Holding (SLT)
0 = Disable (No)
1 = Yes (Enable)
1 11-12-46
09
Caller ID Function - For External Module
Enable/Disable the Caller ID FSK signal for an
external Caller ID module or a 3rd party vendor
telephone with Caller ID display.
Important:
If voice mail is used, this setting must be
disabled for the system integration codes to be
correct.
With a 2500 set (no Caller ID) installed,
this must be set to 0 for incoming callers to
have a talk path.
0 = Disable (Off)
1 = Enable (On)
0
10
Caller ID Name
Determine if an extension user telephone should
display the Caller ID name.
0 = Disable
1 = Enable
1 15-03-09
11
Caller ID Type
Determine whether the Caller ID type is FSK or
DTMF.
0 = FSK
1 = DTMF
0
14
Forwarded Caller ID Display Mode
Determine what the display shows when a
multiline terminal receives a forwarded outside
call.
0 = Calling
Extension
Number
(Calling)
1 = External
Caller ID
(Forward)
0
15
Disconnect without dial after hooking hold
Determine whether or not to disconnect a held
call when on-hook without any dialing after
hooking-hold.
0 = Normal
1 = Disc.
0
16
Special DTMF Protocol Send
Determine whether or not to send the extension
number of the phone forwarded to the extension
when PRG 15-03-03 is set to Special (1) and not
in the VM group.
0 = No
1 = Yes
0
18
Select Special Terminal Type
Select what terminal type transmits data via a
SIP trunk.
0 = Fax
1 = Modem
0 15-03-03
Item
No
Item Input Data Default
Related
Program

Table of Contents