2-202 Program 15 : Extension, Basic Setup
32
Ten Key Pad
Talkie
0 = Off
1 = On
0
33
LAN Side IP
Address of
Terminal
0.0.0.0~255.255.255.255
0.0.0.0 Read-only
34
Terminal Touch
Panel On/Off
0 = Off
1 = On
1 Select whether the touch
screen used on
ITL-320C-1 (BK) TEL
can be used (1) or cannot
be used (0).
35
Encryption
Mode
0 = Off
1 = On
0
36
DT800/DT700
Firmware
Version
00.00.00.00~FF.FF.FF.FF
00.00.00.00
37
DT800/DT700
Large LED
Illumination
Setup
2 = Red
3 = Green
4 = Blue
5 = Yellow
6 = Purple
7 = Light Blue
8 = White
9 = Rotation
3 Sets LED color for
internal Intercom call. In
DT800/DT700 local
terminal setting menu,
illumination setting must
be ‘Automatic’, otherwise
the terminal will ignore
PRG 14-01-35,
PRG 15-05-37 and
PRG 15-23 settings.
38
Paging
Protocol Mode
(With V5000 or
higher, the
default is “1”)
0 = Multicast
1 = Unicast
2 = Auto
1 Sets the protocol mode
for the Paging function.
39
CTI Override
Mode
0 = Disable
1 = Enable
0 Sets the override function
against the terminal that
is controlled by the CTI.
40
Calling Name
Display Info via
Trunk for
Standard SIP
0 = Both name and
number
1 = Name only
2 = Number only
3 = None
0 Sets the incoming calling
name display type on a
standard SIP terminal.
Trunk name is the first
priority and abbreviated
(SPD) name is second
priority.
41
Time Zone
(Hour)
0~24 (-12~+12)
12 Sets the time difference
from the system time set
in Program 10-01. Input
hour(s) based on this
Program.
Item
No.
Item Input Data Default Description