Issue 4.0
SV9100 Programming Manual 2-667
Description
Use Program 51-16: NetLink System Data Replication Mode Setting to set the system data
replication between the Primary and Secondary systems.
Program 51 : NetLink Service
51-16 : NetLink System Data Replication Mode Setting
Level:
IN
Input Data
Item
No.
Item Input Data Default
01
System Data Replication Mode
Set the synchronous mode of the system data. When
set to 1, the systems are synchronized at the time set in
Item 02 below.
When set to 2, the systems are synchronized at regular
time intervals set in Item 03 below.
0 = Disable
1 = Setting Time Mode
2 = Interval Mode
1
02
System Data Replication Time Setting
Set the time of day that both systems synchronize
database (when Item 01 is set to 1.)
0000~2359
0200
03
System Data Replication Interval Setting
Set the time interval that both systems synchronize
database (when Item 01 is set to 2).
15~1440 (minutes)
30 (min)
04
Replication Time Stamp
Show next replication time. (Read-Only)
Month: 0~12
–
Day: 0~31
–
Hour: 00~23
–
Minute: 00~59
–
05
System Data Replication Wait Time
Set the wait time until replication starts when NetLink is
created.
1~86400 (seconds)
180 sec
06
System Data Replication Interval
Set the time to start replication to the next node after
replication to one node is completed.
0~86400 (seconds)
1 sec