EasyManua.ls Logo

NEC Univerge SV9100 - TLI Initial Data Setup

NEC Univerge SV9100
954 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Issue 4.0
2-702 Program 81 : Basic Hardware Setup for Trunk
Description
Use Program 81-03 : TLI Initial Data Setup to define the various basic timers for the E&M Tie Line Unit.
Program 81 : Basic Hardware Setup for Trunk
81-03 : TLI Initial Data Setup
Level:
IN
Input Data
Item Name Input Data Default
01
PCM Method Type
0 = -law
1= A-law
0
02
Answer Signal Time
1~255
(10~2550ms)
6
(60ms)
03
Clear Signal (Open Loop) Detection Time
1~255
(100~25500ms)
7
(700ms)
04
Ringing Signal Detection Minimum Time
1~255
(10~2550ms)
10
(100ms)
05
Ringing Signal Stop Detection Time
1~255
(100~25500ms)
7
(700ms)
06
Hook Flash Time
1~255
(10~2040ms)
20
(200ms)
07
Pause Time
1~255
(60~15300ms)
50
(3000ms)
08
WINK/DELAY Duration Time
1~255
(10~2550ms)
20
(200ms)
09
Incoming-WINK/DELAY Send Time
1~255
(100~25500ms)
3
(300ms)
10
Seizure-WINK/DELAY Receive Max. Time
1~255
(100~25500ms)
48
(4800ms)
11
Receive WINK/DELAY Duration Min. Time
1~255
(10~2550ms)
13
(130ms)
12
Receive WINK/DELAY Duration Max. Time
1~255
(10~2550ms)
31
(310ms)
13
Receive DP Make Minimum Time
1~255
(2~510ms)
5
(10ms)

Table of Contents