EasyManua.ls Logo

NEC Univerge SV9100 - Page 1052

NEC Univerge SV9100
1402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1052
Program
Number
Program Name/Description
Input Data
Default
11-12-64
Service Code Setup (for Service Access)
Security Sensor Mode Start
Service code + 1, after the timer (Program
20-55-01) passes, sensor signal is valid.
Service code + 0, sensor signal is invalid.
MLT, SLT
0 ~ 9,
*
, # Maximum of eight
digits
819
13-04-01
Speed Dialing Number and Name Speed
Dialing Data
Enter the System and Group Speed Dialing
numbers and names.
Maximum of 24 digits.
1 ~ 9, 0, *, #
Pause (Press line key 1)
Recall/Flash (Press line key 2)
@ = Code to wait for answer
supervision in ISDN (Press line
key 3)
No Setting
15-07-01
Programmable Function Keys
Assign a function key for Warning Message
(code
*
32).
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
*
99 (Appearance
Function Code) (Service Code
852 by default)
15-07-01
Programmable Function Keys
Assign a function key for Sensor Mode (code
*
33).
Line Key 1 ~ 48
0 ~ 99 (Normal Function Code
851 by default)
*
00 ~
*
99 (Appearance
Function Code) (Service Code
852 by default)
20-01-19
System Options Emergency Call Setting of
Remote Inspection Feature when the Target
is in Off-Hook Status
Assign to make an emergency call when the
inspection target is in off hook status.
0 = Not Call
1 = Call
0
20-08-23
Class of Service Options (Outgoing Call
Service) Display Indication for Security
Sensor Detection
Enable(1) or Disable(0) an extension’s ability to
display indication for security sensor detection.
0 = Disable
1 = Enable
0
20-08-24
Class of Service Options (Outgoing Call
Service) Display Indication for Emergency
Call by Remote Inspection
Enable(1) or Disable(0) an extension’s ability to
display indication for emergency call by remote
inspection.
0 = Disable
1 = Enable
0
20-21-05
System Option when Long Conversation
Conversation Cutoff for Remote Monitor
0 ~ 64800 seconds
180
20-44-01
Watch Mode Setup Internal Paging Group
for Watch Message
Define Internal paging group number for
Watching message.
0 = No Internal Paging
1 ~ 64 = Internal Paging Group
Number
0

Table of Contents

Other manuals for NEC Univerge SV9100

Related product manuals