EasyManua.ls Logo

NEC Univerge SV9100 - Page 430

NEC Univerge SV9100
1402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
430
Terminals
Multiline Terminal (DT400/DT300)
Required Component(s)
GCD-8DLCA/ GCD-16DLCA or GPZ-8DLCB or GCD-LTA
Related Features
Night Service
Guide to Feature Programming
Program
Number
Program Name/Description
Input Data
Default
11-10-51
Service Code Setup (for System
Administrator) Power Saving for Power
Save Group
Use to determine the Service Code setting for
the Power Save feature (On/ Off) in the Power
Saving Group.
MLT, SLT
0 ~ 9,
*
, # Maximum of eight
digits
731 (NA)
12-02-01
Automatic Night Service Patterns Start
Time
Defines the daily pattern of the automatic mode
switching. Each mode group has 10 patterns.
These patterns are used in Programs 12-03
and 12-04. The daily pattern consists of 20
timer settings.
This option defines the start time.
0000 ~ 2359
12-02-02
Automatic Night Service Patterns End
Time
Defines the daily pattern of the automatic mode
switching. Each mode group has 10 patterns.
These patterns are used in Programs 12-03
and 12-04. The daily pattern consists of 20
timer settings.
This option defines the end time.
0000 ~ 2359
12-02-03
Automatic Night Service Patterns
Operation Mode
Defines the daily pattern of the automatic mode
switching. Each mode group has 10 patterns.
These patterns are used in Programs 12-03
and 12-04. The daily pattern consists of 20
timer settings.
This option defines the operation mode the
system should be in during each time number.
1 ~ 8
1 or 2 depending
on the time
pattern and time
number.